HP (Hewlett-Packard) 132A Water Dispenser User Manual


 
Chapter 2 Command Summary
Front Panel to SCPI Command Maps
Programming Guide 2-17
LIMITS and MATH Keys to SCPI Command Map (Cont.)
1 a. :CALCulate2:LIMit:UPPer[:DATA] <numeric_value> [HZ | S | DEG]
b. :CALCulate2:LIMit:LOWer[:DATA] <numeric_value> [HZ | S | DEG]
2 a. :CALCulate2:LIMit:STATe OFF | ON
b
1
. :INITiate:AUTO OFF
b
2
. :INITiate:AUTO ON
c. :CALCulate2:LIMit:DISPlay GRAPh | NUMBer
3 a. :DISPlay[:WINDow]:TEXT:FEED CALC3 *
:CALCulate3:AVERage:TYPE MAXimum | MINimum |
SDEViation | MEAN *
OR
:DISPlay[:WINDow]:TEXT:FEED CALC2 *
b. :CALCulate3:AVERage:COUNt <numeric_value>
c. :CALCulate3:AVERage[:STATe] OFF | ON
d
1
. :CALCulate3:LFILter:STATe OFF
d
2
. :CALCulate3:LFILter:STATe ON
e
1
. :TRIGger:COUNt:AUTO OFF
e
2
. :TRIGger:COUNt:AUTO ON
4 a. :TRACe[:DATA] SCALE, <numeric_value>
b. :TRACe[:DATA] OFFSET, <numeric_value> [HZ | S | DEG]
c. :CALCulate:MATH:STATe OFF | ON
*Use CALC3:AVER:TYPE and :DISP[:WIND]:TEXT:FEED CALC3to specify
SHOW: STD DEV, MEAN, MAX, or MIN. Use DISP[:WIND]:TEXT:FEED CALC2to
specify SHOW: MEAS.
Figure 2-5. LIMITS and MATH Keys to SCPI Command Map