Figure 9. Select Screen
When the Select menu is displayed, the Unit Data is highlighted. To access the
Unit Data menu, press the GO button. Refer to Table 3, the Select menu, for
button functions.
Unit Data Menu
The Unit Data screen, shown in Figure 10, provides information about the
individual barrels in the system. When DATA is highlighted and the GO button is
pressed on the Select menu, the display shows the first barrel in the system and
some of its parameters. To view the next barrel, press the Down arrow on the
right side of the display. Continue pressing the Down arrow to view the data on
all barrels in the system. Refer to Table 4 for button functions.
Figure 10. Unit Data Screen
Table 3
Button Description
BACK Returns the display to the Barrel Status menu
MAIN Highlighted to indicate current menu
SETUP Opens the Setup menu
MAINT Displays and opens Maintenance menu, if security is off or accessed
GO Opens the highlighted selection on the current menu
BACK MAIN SETUP MAINT GO
SELECT
12:51P
MAR 04
UNIT DATA
ERROR STATUS
ERROR LOG
Table 4
Button Description
BACK Returns the display to the Select menu
BRL Displays the data for a single barrel, including Outlet Temperature, Vis-
cosity, if Refrigeration is On or Off, Average Ounces of product dispensed
per hour for the last three hours and Defrost Lock Time until next defrost
UNIT
DATA
12:51P
MAR 04
#1 FREEZE
OUTLET TEMP 33
o
F
VISCOSITY: 9
REFRIGERATION: ON
DEFROST TIMER: 2:50:23
BACK BRL UNIT VER
AV OZ/HR/3 HR: 80