Cornelius 3 Juicer User Manual


 
Viper Service Manual
© 2010, IMI Cornelius Inc. - 55 - Publication Number: 621360041TBSER
CO2 PULSE VALVE REPLACEMENT
The CO2 valves, shown in Figure 46, are located near the center of the unit and
are mounted on a bracket to the bottom of the chassis. They control the injection
of CO
2 with the syrup/water combination to provide the final mixture for the prod-
uct. There are one of these solenoids for each barrel in the system. When working
in this area, care should be taken not to damage or misalign the CO
2 metering
orfice. To replace one of these valves, perform the procedure in Table 48.
Figure 46. Side View of CO2 Pulse Valves
Figure 47. Front View of CO2 Pulse Valves
Table 48
Step Action
1 Disconnect power from the unit.
2 Disconnect the CO
2 supply from the unit.
3 Remove the rear cover and side panels.
4 Carefully remove the tubing from the rear of the valve.
5 Remove the mounting tie-wrap from the rear of the valve.
6 Replace the valve.
7 Reverse the procedure to reinstall the valve into the unit.
Pulse Valve
(1
OF 3)
Mounting
Tie-Wrap
Pulse Valves