Figure 27. Flow Controls with Panel Removed
Motor Setup Menu
Motor setup is initially done at the factory and does not need to be changed
unless a barrel motor or barrel components are replaced, adjusted or removed
and reinstalled.
This menu allows you to select different motor types for each barrel in the unit
and run the calibration procedure on that motor. This procedure correlates the
actual viscosity of the barrel and its contents with the electrical characteristics of
the motor. These characteristics are stored by the control system and are
accessed at the time of calibration for each particular motor.
Because of the differences between motor characteristics from different motor
suppliers, the Motor menu, shown in Figure 28, is used to adjust the unit settings
to match the motor type being installed. It provides the correct table of electrical
characteristics from imbedded settings located in non-volatile memory. Perform
the procedure described in Table 30 to change the motor type setting. Insure
that the motor type matches the settings listed in Table 28 based on model.
NOTE: If the Motor Type shown is “DEFAULT”, it indicates that the
EEPROM is not installed or is faulty.
Syrup Flow
Control
Water Flow
Control
(Do Not Adjust)
Manual
Syrup Control
Valve
Manual
Water Control
Valve
Table 28
Model Motor Type
All 60 Hz 1
All 50 Hz 2