Cornelius 3 Juicer User Manual


 
Viper Service Manual
© 2010, IMI Cornelius Inc. - 53 - Publication Number: 621360041TBSER
Figure 43. Side View of Motor Showing Two of the Four Mounting Bolts
MOTOR RUN CAPACITOR REPLACEMENT
The motor run capacitors, shown in Figure 44, are mounted at the rear of the
unit between the barrel motors. To replace a run capacitor, perform the proce-
dure in Table 46.
Figure 44. View of Motor Run Capacitors
Table 45
Step Action
1 Perform the procedure in Steps 1 through 8 of Table 42.
2 Disconnect the motor from the circuit by unplugging the connector.
3 Remove the motor by removing the four (4) bolts holding the motor to the bar-
rel assembly.
4 Install the replacement motor and connect the connector.
5 Replace the motor seal, scraper blade assembly onto the motor shaft in the
barrel, as described in Table 42.
6 Reconnect power to the unit.
7 Refill the barrel with product. See “Filling a Barrel” on page 29.
8 When barrel fill is complete, perform a motor calibration. See “Calibrating a
Motor” on page 35.
Barrel Motor
Mounting
Bolts
Foam
Pack
Table 46
Step Action
1 Disconnect power from the unit.
Motor Run
Capacitors