Cornelius 3 Juicer User Manual


 
Viper Service Manual
© 2010, IMI Cornelius Inc. - 49 - Publication Number: 621360041TBSER
Cleaning the Water Filter
The water filter screen in the rear of the unit should be removed and cleaned
every six months, during the preventative maintenance procedures. To inspect
and clean the filter screen, perform the procedure in Table 42. Refer to Figure 34
for water filter location.
Figure 34. Water Filter Location
7. Rotate the Product/BRIX valve to the BRIX position and open the valve at the
end of the tube.
8. Hold a waste container under the BRIX tube to collect the sanitizing solution
from the syrup line and open the manual syrup flow valve to start filling the
syrup line with syrup. Continue to hold open the syrup flow valve until syrup
starts coming out of the BRIX tube.
9. Perform a BRIX setup. See “BRIX Setup Menu” on page 32.
10. Fill the barrel with product as described in Table 22.
11. Perform motor calibration. See “Calibrating a Motor” on page 35.
Table 41
Step Action
Table 42
Step Procedure
1.
Disconnect power from the unit.
2. Turn off and disconnect the water supply to the unit.
3. Remove the rear cover of the unit.
4. Disassemble the water filter. (Use two wrenches, if necessary)
5. Remove the filter and rinse it under running water to remove any debris.
6. Reassembe the filter.
7. Connect and turn on the water supply to the unit.
8. Check the filter for any leaks.
9. Replace the rear cover.
10. Reconnect power to the unit.
Water
Filter