Mitsubishi FR-A5AP Oven User Manual


 
10
I.ISTALLATION
2.INSTALLATION
2.1. Pre-Installation Instructions
(1) Make sure that the input power of the inverter is off and make sure the charge light is off.
(2) When the FR-A5AP unit is used for PLG feedback control or orientation control, a PLG (motor with PLG) and
external power supply are required.
When PLG feedback control and orientation control are used together, the PLG (motor with PLG) and external power
supply are shared between these controls.
(3) When the FR-A5AP unit is fitted, the programmed operation function is made invalid.
CAUTION
With input power on, do not install or remove the option unit. Otherwise, the inverter and option unit
may be damaged.
2.2. Installation Procedure
(1) Securely insert the connector of the option unit far into the connector of the inverter. At this time, also fit the option
fixing holes securely.
(2) Securely fix the option unit to the inverter on both sides with the accessory mounting screws. If the screw holes
do not match, the connector may not have been connected correctly. Check for loose connections.
CAUTION
When installing the inverter front cover, the cables to the inverter's control circuit terminals and option
terminals should be routed properly in the wiring space to prevent them from being caught between the
inverter and its cover.