5.3. Adjustment
(
60Hz
)
0
Pr.386
Pr.385
Output frequency
Bias
Factor
y
settin
g
Maximum number of pulses
Input pulses
(
PPS
)
Gain
Note: Maximum number of input pulses: 100kpps
Note: Number of input pulses are multiplied by 2
internally
5.4. Parameter Definition
Parameter No. Name Setting Range Minimum Increments Factory Setting
384
(Note 1)
Input pulse frequency division ratio 0 to 250 1 0
385 Zero-input pulse frequency 0 to 400Hz 0.01Hz 0
386 Maximum-input pulse frequency 0 to 400Hz 0.01Hz 60
Note: 1. Indicates the frequency division ratio for the input pulses. The frequency resolution to the input pulses
varies with the setting.
2. When the Pr. 384 value is "0" (factory setting), Pr. 385 and Pr. 386 do not function even if their values
have been set.
CAUTION
It should be noted that if the pulse train input command is not given, the motor will start at the preset
frequency by merely switching on the start signal.