50
10) In the vector control mode, the carrier frequency is as follows:
Pr. 72 Setting Carrier Frequency
V/F control, advanced
magnetic flux vector
control
Vector control
0 0.7kHz
1 1kHz
2 2kHz
Approximately 1kHz
3 3kHz
4 4kHz
5 5kHz
Approximately 3kHz
6 6kHz
7 7kHz
8 8kHz
9 9kHz
10 10kHz
11 11kHz
12 12kHz
13 13kHz
14 14kHz
15 14.5kHz
Approximately 6kHz
(Note 1)
Note: 1. When the capacity of the inverter is the same as that of the motor, do not set "6" or a higher value in Pr.
72 "PWM frequency selection".
When the capacity of the inverter is one rank higher than that of the motor, "6" (appoximately 6KHz) or a
higher value may be set in Pr. 72 "PWM frequency selection".
2. In the vector control mode, set the Pr. 72 "PWM frequency selection" value during a stop.