Mod el 5454 Operat ing Procedures
080911
Sanitizing
Step 1
Prepare a mix pail of appr oved 100 P PM sanitizing
solution (examples: 2- 1/2 gal. [9.5 liters] of Kay- 5R
or 2 gal. [7.6 liters] of Stera- SheenR). USE WARM
W ATE R AND FOLLOW THE MANUFACTURER’S
SPECIFICATIONS. Place the pail of sanitizing solu-
tion inside th e mix cabinet .
Figure 37
Step 2
Dip the long brush in the sanitizing solution and brus h
clean the mix inlet tube.
Figure 38
Step 3
Connect the free end of the flare line to the threaded
fitting on the mix inlet tube.
Figure 39
Step 4
Insert the free end of the s uction line into the pail of
sanitizing s olution.
Figure 40
Step 5
Place the power s witch in the ON position.
Figure 41