Troubleshooting Guide Mod el 5454
PROBLEM PROBABLE CAUSE REMEDY PAGE
REF.
4. The mix cabinet
temperature is too
warm.
a. Warm mix was placed in the
cabinet.
a. Mix placed in the mix tank
should be below 40_F
(4.4_C).
--
b. The soft ech contr ol needs to
be adjust ed.
b. Call a service technician to
adjust the softech control.
--
c. The mix cabinet door was left
open.
c. The door must be kept closed.
28
d. The mix cabinet door gasket
is not sealing.
d. Repair or replac e the door
gasket.
--
e. The condenser on air cooled
units is dirty.
e. Clean condensers regularly.
37
5. The mix cabinet
temperature is too
cold.
a. The soft ech contr ol needs to
be adjust ed.
a. Call a service technician to
adjust the softech control.
--
6. Syrup is b leeding into
the freezing cylinder .
a. The spinner shaft w as
improperly installed.
a. The spinner blade must be
flush with the bottom o f the
door s pout.
20
b. The center o- ring on the draw
valve w as improperly
lubricated or worn.
b. Lubricate the o- ring properly,
or r eplace every 3 months.
44
c. The draw handle is not
completely closed.
c. Push the draw handle u p
completely.
--
7. Product is collecting
on top of the draw
valve.
a. There is inadequate
lubrication on the spinner
shaft.
a. Lubricate the spinner shaft
properly.
20
8. Product is collecting
on top of the freezer
door.
a. The top o- ring on the draw
valve i s improperly lubricat ed
or wor n.
a. Lubricate properly or replace
every 3 months.
44
9. There is excessive
mix l eakage from the
bottom o f the door
spout.
a. There is a worn, missing, or
incorrect o- ring on the draw
valve.
a. Replace rubber par ts ever y 3
months. Check the o- r ing
size.
44
b. There is improper lubrication
on the draw v alve o- rings.
b. Lubricate the o- rings properly.
19
c. There is inadequate
lubrication on the spinner
shaft.
c. Lubricate the spinner shaft
properly.
20