To the Installer Model 5454
131212
Water Connections
(Water Cooled Units Only)
An adequate cold water supply must be provided with
a hand shut- off valve. On the underside rear of the
unit, two 3/8” I.P.S. water connections for inlet and
outlet have been prov ided for easy hook- up. 1/2”
inside diameter water lines should be connected to the
machine. (F lexible lines are recommended, if local
codes permit. ) Depending on local water condit ions, it
may be advisable to install a water strainer to prevent
foreign substanc es from clogging the automatic water
valve. There will be only one water “in” and one wate r
“out” connection. DO NOT install a hand shut- off valve
on the water “out” line! Water should always flow in this
order: firs t, through the automatic water valve; second,
through the condenser; and third, through the outlet
fitting to an opentrapdrain.
A back fl ow preventi on device is required
on the incoming water connection side. Please
refer to the applicable National, State, and local codes
for determining the proper c onfiguration.
Electri cal C onnections
In the Unite d States, this equipment is intended to be
installed in accordance with the National Electr ical
Code (NEC), ANSI/NFPA 70-1987. The purpose of the
NEC code is the practic al safeguarding of persons and
property from hazards arising from the use of
electric ity. This code contains provisions considered
necessary for safety. In all other areas of t he world,
equipment should be inst alled in accordance with the
existing local c odes. Please c ontact your local
authorities.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
Each fr eezer requires one power supply for each data
label. Check the data labels on the freezer for branch
circuit o vercurrent protection or fuse, wire a mpacity
and electrical spec ifications. Refer to the wiring
diagram provided inside of the cont rol box, for proper
power c onnections.
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDE D! F AILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
This unit is provided with an equipotential
grounding lug that is to be properly attached to the r ear
of the frame by the authorized installer. Th einst allation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipment’s frame.
S Stationary appliances which are not
equipped with a power cord and a plug or
another device to disconnect the appliance
from the power source must have an all-pole
disconnect ing device with a contac t gap of
at least 3 m m installed in the external
installati on.
S Appliances that ar e permanently connect ed
to fixed wiring and for w hich leakage
current s may exceed 10 mA , particularly
when disconnected or not used for long
periods, or during i nitial installation, shall
have protective dev ices such as a GFI, to
protect against the leakage of current,
installed by the authorized personnel to the
local c odes.
S Supply cords used with this unit shall b e
oil-resistant , sheathed flexible c able not
lighter than ordinary polychloroprene or
other equivalent synthet ic
elastomer-sheathed cord (Code designation
60245 IE C 57) inst alled with the proper cord
anchorage to relieve conductors from strain,
including twisting, at the terminals and
protect the insulation of the c onductors from
abrasion.
If the supply cord is dam aged, it must be
replaced by an authorized Taylor service
technician in order to avoid a hazard.