Taylor 5454 Refrigerator User Manual


 
42
Troubleshooting Guide Mod el 5454
PROBLEM PROBABLE CAUSE REMEDY PAGE
REF.
14. Large pressure
adjustments are
needed to calibrate
the syrups or unable
to get adequate syrup
delivery with syrup
sampler.
a. There is hardened syrup in
the syrup lines.
a. Clean and sanitize the s yrup
lines week ly.
35
b. The syrup and air lines are not
matched.
b. Match the color spiral air and
syrup line to the correct syrup
tank.
28
c. There is a plugged restrictor in
the vanilla or strawberry syrup
line connection.
c. Clean the restrictor. Remove
the air line fr om the syrup
tank. Remove the syrup line
(vanilla or strawberry) from
the syrup tank. Disassemble
the syrup quick disconnect.
Pull the res trictor out and
clean.
--
d. The syrup line fitting is
plugged at the fr eezer door
connection.
d. Clean the s yrup line fitting.
16
15. The pump will not
operate.
a. The pump m otor may b e off
on reset.
a. Push the reset button on the
pump m otor.
--
16. The machine will not
run while in AUTO.
a. The machine is unplugged. a. Plug the mac hine into the wall
receptac le.
--
b. The circuit breaker is of f, or
thefuseisblown.
b. Turn the breaker on, or
replace the fuse.
--
c. The machine is low on m ix.
The MIX OUT light is on.
c. Add mix to the mix tank.
--
d. The mix probe is not installed
properly.
d. Check the mix probe
installati on.
27
e. The beater motor i s out on
reset.
e. Reset the freezer .
14