Taylor 5454 Refrigerator User Manual


 
26
Operat ing Procedures Mod el 5454
110210
Step 6
Place an empty mix pail beneath the door spouts and
raise the prime p lug.
Figure 42
Press the WASH and PUMP keypads. The lights will
come on, indicating the pump and beater motor are
operating. When a steady stream of sanitizing soluti on
is flowing from the bleed port in the bottom of the
freezer door, press the PUMP keypad, stopping the
pump operation. Push down the prime plug. Allow the
sanitizing solution to agitatein the freezing cylinder for
five minutes.
Figure 43
Step 7
Afte r five minutes, raise the prime plug and press the
PUMP keypad. Pull down all three d raw handles and
draw off the remaining sanitizing solution.
Figure 44
Step 8
Once the sanitizer stops flowing from the door spouts,
close the draw valves. Press the W ASH and PUMP
keypads to stop operation.
Figure 45
Note: You have just sanitized the fr eezer. Be
sure your hands are sanit ized before continuing
these instructions.