Mod el 5454 To the Installer
131212
Beater Rotation
Beater rotation must be clockwise as viewed
looking into the freezing cylinder.
Note: T o preven t personal in jury and
damage to the equipment, the following
procedures must be performed by an authorized
Taylor service technici an.
Correct rotation on a three- phase unit by
interchanging any two incoming power supply lines at
the freezer m ain terminal block only.
Correct rotation on a single- phase unit by changing
the leads inside the beater motor. (F ollow the diagram
printedonthemotor.)
Electr ical connections are made directly to the
terminal bloc k. The terminal bloc k i s provided in the
splice boxes located behind the left and right side
panels.
Refrigerant
In consideration o f our environment, Taylor
uses only HFC refrigerant s. The HFC refr igerant used
in this unit is R404A. This refr igerant is generally
considered non-toxic and non-flammable, with an
Ozone Depleting Potential (ODP) of zero (0).
However , any gas under pressure is potentially
hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with
liquid. Filling the cylinder to approximately 80% will
allow for normal expansion.
Use only R404A refrigerant that conforms to
the AHRI standard 700 specification. The use of any
other refrigerant may expose users and operators to
unexpected s afety hazards.
Refrigerant liquid spr ayed onto the s kin may
cause serious damage to tiss ue. Keep eyes and skin
protected. If refrigerant burns should occur , flush
immediately with cold water. If burns are severe, apply
ice pac ks and c ontact a physician immediately.
Taylor reminds technicians to be aware of and
in compliance with local gov ernment laws regarding
refrigerant recovery, r ecycling, and reclaiming
systems. For information regarding applicable local
laws, please contact your local authorized Taylor
distributor.
W ARNING: R404A refrigerants used in
conjunction with polyolester oils are extremely
moisture absorbent. When opening a refrigerat ion
system, the maximum time the system is open must
not exceed 15 minutes . Cap all open tubing to prevent
humid air or water fr om being absor bed by the oil.