Section 2. Washer Controls Overview
screen test failed." In either case the
screen will step to the next screen to
check the membrane switches.
This test checks the membrane switches
on the console pad.
The screen displays the status of the
touch screen test that was just performed.
The technician is then prompted to
Press the 5 keypads in any order." When
each key is pressed, it will display in
reverse image and remain that way. If all
keys are sensed, the control will display
Membrane switch test passed." If any
key(s) is not sensed within 10 seconds,
the technician will be prompted to Touch
the key(s) that are not highlighted." If
key(s) again are not sensed within 10
seconds, the control will display which
key(s) failed.
The last step of the user interface test is to
display the entire screen in reverse image
for 2 seconds and then resume normal
display mode. This is done as soon as
the membrane switch test is complete.
This is a visual test only.
Service Cycle
The service cycle can be run during a
wash/spin cycle or can be used to initiate
a particular cycle in the washer. To access
this, select service cycle in the Service
Mode.
User Interface
Test
exit user
interface test
Touch screen test passed.
Press the switches in any order.
home
favorites
back
help
start/pause
off
Service Cycle
Press "start
service cycle"
or start/pause
button to
begin service
cycle
start service
cycle
system check
cancel & exit
service cycle
Service Cycle
cancel cycle
system check
cancel & exit
service cycle
To start a wash cycle in the Service Cycle:
If the washer is not operating in a wash
cycle, touch the icon start service cycle
or start/pause key to begin the service
cycle.
During a cycle:
While the washer is running, and service
cycle is selected, the following screen will
display and you can perform system
checks of the various inputs and outputs
of the washer by selecting system check.
(See System Check)