16008373-01 SECTION 6. WATER CARRYING COMPONENTS
6-6
Figure 6-9
Drain Hose
Access
Cover
Figure 6-10
Drain Hose
Clamp
DRAIN HOSE
The drain hose attaches to the pump and is
routed through the lower rear wall of the cabi-
net. The drain hose is protected externally by
a shield.
REMOVAL
1. Disconnect power to the unit.
2. Remove the four ¼" hex head screws se-
curing the access panel to the rear wall of
the cabinet.
3. Remove the ¼" hex head screw securing
the drain hose shield. Remove shield.
4. With access into the machine compart-
ment, spread a towel under the connec-
tion of the drain hose to the pump. Loosen
the clamp and remove the drain hose
(Fig-
ure 6-10).
5. Reverse the previous steps for
replacement.