As a result of this revision, a new dis-
penser bottom, water valve and hoses
were introduced. (See Figure 8-2)
OPERATION:
When Bleach or Fabric Softener is re-
quired to dispense, the dedicated sole-
noid on the water valve is activated the
same as the previously used wax motor.
Water is directed to dedicated spouts on
the dispenser bottom. (See Figure 8-3)
Inside the dispenser bottom, water is
directed into the designated channels
leading to the siphon cup assembly.
RECIRCULATION PUMP
The Recirculation Pump is accessible
from the front or the rear of the machine.
The pump is connected in series with the
outer tub pump hose and the drain hose.
(See Figure 8-4)
1. Disconnect power and water to the
machine.
2. Remove the front panel.
3. Lay a towel under the tub to pump
hose and loosen the clamp on the
pump connection to the hose.
4. Loosen the clamp on the detergent
hose connected to the side of the
recirculation pump.
5. Lift the recirculation pump at an angle
to disengage the locating tab of the
mounting bracket from the baseframe.
(See Figure 8-5)