©2001 Maytag Appliances Sales Company
2-17
16010486 (16008373-05)
Revised 02/01
Section 2. Washer Controls Overview
The service cycle will advance the washer
through various parts of the wash cycle
and will display the following on the
control panel.
Cold water fill
During the second step of the test, the
technician will be prompted to Open
and close the door and then restart by
pressing start/pause.
Locking the door, Cold water and
bleach fill and Warm water and bleach
fill
Tumble
Hot water fill
Hot water and fabric softener fill and
Warm water and fabric softener fill
Static drain
Spin
Coast down and unlock at 0 RPM
Service cycle complete
Advance to next step: When this icon is
selected during the cycle, it will advance
to the next step in the service cycle.
Note: This selection is valid only if a
cycle is running.
Select start quick spin test or start/
pause key to begin quick spin test.
The default is that the tuning algorithm will
apply, but it can be skipped. Plaster
detection will default to disabled, but can
be enabled.
Quick Spin
Test
enable plaster
unbalance
detection
Press "start quick spin test" or start/pause
button to begin quick spin test
skip tuning
algorithm
cancel & exit
quick spin test
start quick
spin test
Quick Spin Test
cancel cycle
cancel & exit
quick spin test
The following will be displayed during
the quick spin test:
Locking the door
Spin to 350 RPM
Spin to 550 RPM
Spin to 600 RPM
Spin to 650 RPM
Spin to 800 RPM
Spin to 1000 RPM
Coast down and unlock at 0 RPM
Quick spin test complete
Any of the steps in this test can be held or
paused up to 30 minutes, by touching the
start/pause key..
Skip tuning algorithm: When selected,
the tuning algorithm will be skipped. This
must be selected before tuning.
Enable plaster unbalance detection:
When selected, plaster unbalance
detection will be enabled. This must be
selected before spin starts.
Cancel & exit quick spin test: this
returns you to the service tests screen.
If the washer is already running and the
quick spin test is selected on the service
test screen, the above screen will be
displayed.