Editing PEPs
EncrypTight User Guide 151
Pushing the Configuration
After you define the PEP configurations, push the configurations from ETEMS to the targeted PEPs.
To push ETEMS configurations to PEPs:
1 In the ETEMS Appliances view, select the target PEPs.
2On the Tools menu, click Put Configurations.
3 Some appliance models must be rebooted for configuration changes to take effect. Rebooting
interrupts the data traffic on the PEP’s remote and local ports for several minutes. To reboot the PEP
immediately following a successful put operation, click the Reboot appliances after operations
complete check box on the Put Configurations window. Clear the check box to reboot at a later time.
4 In the Put Configurations window, click Put to push configurations.
5Click Close to return to the Appliances view, and then refresh the appliance status (Tools > Refresh
Status). If you chose to reboot the PEPs after loading the configurations, wait a few minutes for the
reboot operation to complete before refreshing the status.
Related topic:
“Pushing Configurations to Appliances” on page 97
Editing PEPs
PEP configurations can be edited from ETEMS or ETPM. To simplify the editing process, we
recommend editing all PEPs from ETEMS, where you can edit configurations and push them to the PEPs.
If you edit a PEP from ETPM, you will have to switch to ETEMS to push the modified configuration to
the PEP.
Related topics:
“Editing PEPs From ETEMS” on page 151
“Editing Multiple PEPs” on page 152
“Editing PEPs From ETPM” on page 152
“Changing the IP Address of a PEP” on page 153
Editing PEPs From ETEMS
To edit a PEP’s configuration:
1 In the ETEMS Appliances view, select the PEP.
2On the Edit menu, click Configuration.
3 In the appliance editor, modify the configuration. Refer to Table 39. To change all of the values to
their defaults, click Use Defaults.
4 When you are done, click OK. The modified configuration is saved for subsequent downloading to
the PEP.
5 For the new configuration to take affect in the PEP, you must push the configuration to the PEP. In
addition, some changes might require you to reboot the PEP.