Model PH61 Important: To the Operator
Operator Menu
The OPERATOR MENU is used to enter the
operator function displays. To access the
OPERATOR MENU, simply press the MENU key.
The cursor will flash over the letter “A” indicating that
this is screen “A”. To select a different screen, use
the arrow keys and move the cursor to the desired
screen selection and press the SEL key.
OPERATOR MENU
A
B C D E F G H I J
EXIT FROM MENU
<--- ---> SEL
Screen “B” is FAULT DESCRIPTION. The fault
description will indicate if there is a fault with the
freezer and the side of the freezer where the fault
occurred. To clear the tone for any faults which have
been corrected, press the left arrow key. To see if
there is more than one fault per cylinder, press the
SEL key. When the last fault is displayed, the control
will return to the OPERATOR MENU. To return to
the main screen, move the cursor to “A” and press
the SEL key again. Listed below are the variable
messages which will appear, along with the
corrective action:
1. NO FAULT FOUND: There was no fault found
in the freezer. Nothing will appear on the
screen after this variable message appears.
2. BEATER OVERLOAD: Press the reset button
firmly. Clear the tone.
3. HPCO COMPRESSOR: Place the power
switch in the OFF position. Wait 5 minutes for
the machine to cool. Place the power switch in
the ON position. Clear the tone.
4. COMP ON TOO LONG: Place the power
switch in the OFF position. Call service
technician. Clear the tone.
5. HOPPER THERM BAD: Place the power
switch in the OFF position. Call service
technician.
6. BARREL THERM BAD: Place the power
switch in the OFF position. Call service
technician.
7. GLYCOL THERM BAD: Place the power
switch in the OFF position. Call service
technician.
8. HOPPER OVER TEMP: The hopper
temperature has risen too high as follows. Clear
the tone.
a. The hopper temperature reaches 41_F
(5_C) or higher after a power failure.
b. The hopper temperature has not fallen
below 41_ F(5_C) by the end of the COOL
phase in the heat cycle.
9. BARREL OVER TEMP: The barrel temperature
has risen too high as follows. Clear the tone.
a. The barrel temperature reaches 41_F
(5_C) or higher after a power failure.
b. The barrel temperature has not fallen
below 41_F(5_C) by the end of the COOL
phase in the heat cycle.
10. POWER FAILURE: This message will appear
in the FAULT DESCRIPTION if a power failure
has occurred. Clear the tone.
FAULT DESCRIPTION
VARIABLE MESSAGE
CLR SEL
Screen “C” is SET CLOCK. This option allows the
Manager to adjust the control clock date and time.
The date and time may only be changed after the
freezer has been manually cleaned but before it has
been placed in the AUTO or STANDBY mode. The
following message will be displayed if the SET
CLOCK option is selected when the machine is not
in a brush clean state.
SET CLOCK
12:01 7/21/2007
NO CHANGES ALLOWED
Press Any Key