29
Model PH61 Operating Procedures
Step 15
With the stopping tab of the draw handle facing
down, slide the fork of the draw handle into the slot
of the draw valve. Secure the draw handle with the
pivot pin. (See Figure 21.)
Figure 21
Step 16
Lubricate the shaft of the spinner blade up to the
groove. (See Figure 22.)
Figure 22
Step 17
Insert the spinner blade shaft from the bottom, into
the center of the driven spinner, and up through the
draw valve cavity until the shaft appears at the top of
the draw valve. The spinner blade must be aligned
and engaged to the driven spinner at the bottom.
This allows the spinner shaft to raise high enough to
be engaged into the spinner coupling at the top.
(See Figure 23.)
Figure 23
Step 18
Raise the locking collar of the spinner coupling and
insert the spinner shaft into the cavity of the coupling
until the locking collar can drop into the locked
position. (See Figure 24.)
Figure 24