40
Model PH61Operating Procedures
Step 4
Return to the freezer with a small amount of
sanitizing solution. With a pail below the door spout,
dip the door spout brush into the sanitizing solution
and brush clean the syrup ports in the freezer door,
door spout, bottom of the driven spinner and spinner
blade, and syrup line fittings. (See Figure 55.)
Figure 55
Note: To assure sanitary conditions are maintained,
brush clean each item for a total of 60 seconds,
repeatedly dipping the brush in sanitizing solution.
Step 5
With the syrup port brush, brush each syrup port
hole10to15times.Dipthebrushinsanitizing
solution before brushing each port. (See Figure 56.)
Figure 56
Step 6
Fill the squeeze bottle with sanitizing solution. With a
pail beneath the door, insert the tube end of the
squeeze bottle into the syrup port, and squeeze the
bottle firmly. This action will force solution out of the
adjacent port and down around the spinner. This
procedure should be performed for at least 10
seconds per port. (See Figure 57.)
Figure 57
Step 7
Install the restrictor cap on the freezer door spout.
(See Figure 58.)
Figure 58
Step 8
Using a clean, sanitized towel, wipe down the
freezer door and area around the bottom of the
freezer door.