Henny Penny 600 Fryer User Manual


 
Model 500/600
2-6. GAS SUPPLY The gas fryer is factory available for either natural or propane gas.
Check the data plate on the right side panel of the cabinet to deter-
mine the proper gas supply requirements. The minimum supply for
natural gas is 7 inches water column (1.7 kPa), and 10 inches water
column (2.49 kPa) for propane. Maximum gas supply is 14 inches
water column (3.49 kPa, or .5 psi.
Do not attempt to use any gas other than that specified
on the data plate. Conversion kits can be installed by
your distributor if required. Incorrect gas supply could
cause an explosion or fire resulting in severe injuries
and/or property damage.
1207 2-5