Henny Penny 600 Fryer User Manual


 
Model 500/600
3-10. CHANGING THE
FILTER ENVELOPE
(Continued)
6. Unthread the suction standpipe from the screen assembly.
7. Remove the sealer bar and discard the filter envelope.
8. Clean the top and bottom filter screen with soap and water.
Rinse thoroughly with hot water.
Be sure that the filter screens, sealer bar, and the suction
standpipe are thoroughly dry before assembly of filter envelope
as water dissolves the filter paper.
9. Assemble the top filter screen to the bottom filter screen and
slide the screens into a new filter envelope.
Step 6
Step 7
Step 9
1207 3-21