7. Turn main power switch to ON position.
8. Wait about 45 seconds for the burner to light.
9. Listen for the gas burner ignition.
It will be an audible sound due to the gas igniting at the gas
jets within the burner.
10. The burner lights and operates until the shortening temperature
reaches a preset temperature, and lights.
Do not leave the burner on for more than 10 seconds
without shortening in the frypot or damage to the frypot may
result.
Shutdown Procedure
1. Turn main power switch to OFF position.
2. Turn the gas valve knob counterclockwise to the OFF position.
2-10. GAS PILOT & BURNER
LIGHTING AND
SHUTDOWN
PROCEDURE (Continued)
2-10 1207
2-11. PILOT FLAME
ADJUSTMENT
The pilot flame is preset at the factory. If adjustment is necessary,
contact your local independent Henny Penny distributor.
2-12. PRESSURE
REGULATOR
ADJUSTMENT
(GAS ONLY)
The gas regulator is preset at the factory at 3.5 inch water column
(0.87 kPa) for natural gas (10.0 inch (2.49 kPa) for propane). If
adjustment is necessary, contact your local independent Henny Penny