Henny Penny 600 Fryer User Manual


 
Model 500/600
DISPLAY CAUSE PANEL BOARD CORRECTION
“E-15” Drain switch Close drain, using the drain valve handle; if display still
“DRAN IS failure shows “E-15”, have the drain microswitch checked
OPEN”
“E-20C” Ignition module(s) Turn switch to OFF, then back to COOK to try the ignition
(SSI gas fryers failure process again, and if “E-20C” persists, have ignition modules
only) checked
“E-20D” No ignition Turn switch to OFF, then back to COOK to try the ignition
(SSI gas fryers process again, and if “E-20D” persists, have gas valve and gas
only) flow checked
“E-41” Programming Turn switch to OFF, then back to COOK; if display shows any
“E-46” failure of the error codes, try to reinitialize the control (Section 2-3);
if error code persists, have the control board replaced
“E-70A” Missing or broken Have jumper wire between pins 1 and 2 checked
wire in pins 1 and
2 of P11 connector,
or faulty connector
Faulty I/O board Have I/O board checked and replaced, if necessary
“TEMP TOO” Possible water Make sure oil is in frypot and at the proper level
LOW FOR in frypot
PRESSURE”
3-2. ERROR CODE TABLE
(Continued)
108 5-3