Henny Penny 600 Fryer User Manual


 
Model 500/600
3-12. CLEANING THE
DEADWEIGHT ASSEMBLY
At the end of each day, the deadweight assembly valve must be
cleaned as follows:
DO NOT ATTEMPT TO REMOVE DEADWEIGHT
CAP WHILE FRYER IS OPERATING. SEVERE
BURNS OR OTHER INJURIES WILL RESULT.
1. Turn the main power switch to the OFF position. Be sure all
pressure has been released and open the lid.
2. Unscrew the deadweight cap and remove the cap and dead
weight.
Deadweight cap may be hot. Use protective cloth or
glove, or burns could result.
Failure to clean the deadweight assembly daily could
result in the fryer building too much pressure. Severe
injuries and burns could result.
3. Clean the exhaust tube with stainless steel brush (Henny Penny
part number 12147).
Step 3
1207 3-25
4. Clean the deadweight cap and weight in hot detergent water.
Make certain to thoroughly clean the inside of the valve cap and
the deadweight.
5. Clean the deadweight orifice and the inside of the deadweight
assembly body with a clean lint-free cloth.
6. Dry the deadweight and deadweight assembly cap.
7. Replace deadweight and deadweight assembly cap. Finger
tighten the cap.
Step 6