Model 500/600
2-14. ELECTRICAL
REQUIREMENTS
(GAS FRYER)
The gas fryer requires 120-volt, single-phase, 60-Hertz, 10-amp,
3-wire grounded (earthed) service, or 230-volt, single-phase, 50-Hz,
5 amp, 1 phase service. The 120-volt gas fryer is factory equipped
with a grounded (earthed) cord and plug for your protection against
shock, and should be plugged into a three prong grounded (earthed)
receptacle. Do not cut or remove grounding (earthing) prong. A
wiring diagram is located behind the right side panel, and can be
accessed by removing the side panel. The 230-volt plug must conform
to all local, state, and national codes.
2-12 1207
Do not disconnect the ground (earth) plug. This fryer
MUST be adequately and safely grounded (earthed) or
electrical shock could result. Refer to local electrical
codes for correct grounding (earthing) procedures or in
absence of local codes, with The National Electrical Code,
ANSI/NFPA No. 70-(the current edition). In Canada, all
electrical connections are to be made in accordance with
CSA C22.1, Canadian Electrical Code Part 1, and/or local
codes.
To avoid electrical shock, this appliance must be equipped
with an external circuit breaker which will disconnect all
ungrounded (unearthed) conductors. The main power
switch on this appliance does
not disconnect all line
conductors.