Hot Plug Backplane
Installation
NCR S10XL Hot Plug Server User Guide D-13
You can install a RAID controller and have it connected
to the backplane.
To install the backplane board when you are using a
RAID controller board, follow these steps:
1. Set the terminator switches on the backplane
according to your planned SCSI channel
configuration. Refer to the “SCSI Channel
Configuration” section of this appendix for the
channel configurations.
2. Define the SCSI drive IDs by setting the SCSI ID
jumpers on the hard disk drive.
3. Install the backplane and secure it with eight screws.
Refer to Figure D-5.
4. Connect three power cables into the connectors at
the back of the backplane board.
5. Connect one end of each of the SCSI cables to the
channels on the RAID controller board and the other
end to the corresponding channels on the backplane.
Figure D-9 shows how to connect the cables
properly.
The SCSI cables are specifically marked and
configured for each of the channels.
Using a RAID
Controller Board