Installation
4
Delivery and Location
DELIVERY AND INSPECTION
All Blodgett ovens are shipped in containers to
prevent damage. Upon delivery of your new oven:
D
Inspect the shipping container for external dam -
age. Any evidence of damage should be noted
on the delivery receipt which must be signed by
the driver.
D
Uncrate the oven and check for internal dam -
age. Carriers will accept claims for concealed
damage if notified within fifteen days of delivery
and the shipping container is retained for in-
spection.
The Bl odgett Oven Company cannot assume
responsibility for l oss o r damage suffered in
transit. The carrier assumed full r esponsibility
for delivery in good order when the shipment
was accepted. We are, however, prepared to
assist you if filing a claim is necessary.
OVEN LOCATION
The well planned and proper placement of your
oven will result in long term operator convenience
and satisfactory performance.
The following clearances must be maintained be-
tween the oven and any combustible or non-com -
bustible construction.
DFG100
D
Oven body right side --- 2” (5cm)
D
Oven body left side --- 2” (5cm)
D
Oven body back --- 0” (0cm)
D
Oven body bottom --- 6” (15cm)
DFG200
D
Oven body right side --- 6” (15cm)
D
Oven body left side --- 6” 6” (15cm)
D
Oven body back --- 6” (15cm)
D
Oven body bottom --- 6” (15cm)
The following clearances must be available for ser-
vicing.
D
Oven body sides --- 12” (30cm)
D
Oven body back --- 12” (30cm)
NOTE: On gas models, routine servicing can usu-
ally be accomplished within the limited
movement provided by the gas hose re-
straint. If the oven needs to be moved fur-
ther from the wall, the gas must first be
turned off and disconnected from th eoven
before removing the restraint. Reconnect
the restraint after the oven has been re-
turned to its normal position.
It is essential that an adequate air supply t o t he
oven b e maintained to provide a sufficient flow of
combustion and ventilation air.
D
Place the oven in an area that is free of drafts.
D
Keepthe oven area free and clearof all combus-
tiblessuch as paper, cardboard, and flammable
liquids and solvents.
D
NSF requires 6” of clearance on the bottom and
sides of the unit for cleaning. Do not place the
oven on a curb base or seal to a wall.
D
The location must provide adequate clearance
for the air opening into the combustion cham-
ber.
Before making any utility connections to this oven,
check t he rating plate to be s ure the oven specifi-
cations are compatible with the gas a n d electrical
services supplied for the oven.
1. Remove the combustion compartment cover.
The rating plate is attached tothe frame on the
left side of the combustion compartment.