Cornelius 326142000 Beverage Dispenser User Manual


 
18326142000
‘‘ERROR RESET’’ Control Switch.
‘‘ERROR RESET’’ control switch, located on control panel (see Figure 5), is a touch-type switch and requires
only pressing to activate. ‘‘ERROR RESET’’ switch is used to restore normal operation after error within Unit
(indicated by ‘‘ERROR 1’’ or ‘‘ERROR 2’’ on message display) has been corrected.
‘‘SECURITY SWITCH.’’
The Unit is equipped with a hidden ‘‘SECURITY SWITCH’’ located between ‘‘FILL 1’’ switch and ‘‘ERROR
RESET’’ switch on control panel (see Figure 5). Pressing in and holding ‘‘SECURITY SWITCH’’ for 3-seconds
deactivates control switches preventing tampering with Unit normal operation. To reactivate control switches,
press in and hold ‘‘SECURITY SWITCH’’ for 3-seconds.
CONTROL PANEL DISPLAY MESSAGES
(see Figure 5)
‘‘FILL 1’’ and ‘‘FILL 2’’ Fault Messages.
‘‘FILL 1’’ and ‘‘FILL 2’’ fault messages will appear on message display only when ‘‘FILL 1’’ and ‘‘FILL 2’’ control
switches have been pressed and syrup systems sold-out floats have been filled with product. ‘‘FILL 1’’ and ‘‘FILL
2’’ fault messages will continue to be displayed until ‘‘AUTO BLEND 1’’ or ‘‘AUTO BLEND 2’’ control switches
have been pressed to fill product blender tanks with product.
‘‘ERROR 1’’ and ‘‘ERROR 2’’ Fault Messages.
‘‘ERROR 1’’ and ‘‘ERROR 2’’ fault messages will appear on message display only if error within Unit has
developed interrupting normal operation. Error will have to be located and corrected, then press ‘‘ERROR
RESET’’ to restore normal operation. ‘‘ERROR 1’’ or ‘‘ERROR 2’’ fault message will disappear from display.
‘‘OFF 1’’ and ‘‘OFF 2’’ Fault Messages.
‘‘OFF 1’’ and ‘‘OFF 2’’ fault messages will appear on message display when either freeze cylinder beater is not
operating.
‘‘H
2
O OUT’’ Fault Message.
The Unit plain water inlet system contains a water pressure switch. Should the plain water source to the Unit be
disrupted or a water pressure drop occur, will cause ‘‘H
2
O OUT’’ fault message to appear on message display.
Unit will continue to operate for 1-1/2 minutes after ‘‘H
2
O OUT’’ fault message has appeared and if water
pressure has not been restored or water pressure improved after 1-1/2 minutes, Unit operation will shut down.
After plain water source has been restored or water pressure has improved, Unit will resume operation and
‘‘H
2
O OUT’’ fault message will disappear from message display.
‘‘CO
2
OUT’’ Fault Message.
‘‘CO
2
OUT’’ fault message will appear on message display when CO
2
supply to Unit has been turned off or if
CO
2
pressure drops below 50-psi. A minimum CO
2
pressure of 75-psi must be available to Unit to extinguish
‘‘CO
2
OUT’’ fault message.
‘‘SYRUP 1’’ or ‘‘SYRUP 2’’ Fault Messages.
‘‘SYRUP 1’’ or ‘‘SYRUP 2’’ fault messages will appear on message display if product tanks are not connected to
Unit or product tanks are empty. Syrup systems syrup float switches must be filled with syrup to extinguish
‘‘SYRUP 1’’ or ‘‘SYRUP 2’’ fault messages.