Cornelius 326142000 Beverage Dispenser User Manual


 
44
326142000
BRIX A
11.0 0.1358
11.5 0.1420
12.0 0.1481
12.5 0.1543
13.0 0.1605
13.5 0.1667
14.0 0.1728
14.5 0.1790
15.0 0.1852
15.5 0.1914
16.0 0.1975
GALLONS = A x SYRUP MINUTES
Using the above table, choose the A number that corresponds to your BRIX setting. Multiply the A
number by the syrup minutes reading to obtain the amount (gallons) of syrup used.
TABLE 8. TOTALS (DISPLAYED CYCLES AND HOURS TOTALS) MENU
ITEMS AFFECTED BY ERROR
MESSAGE
DISPLAY ERROR
BEATER
MOTOR 1
BEATER
MOTOR 2 REFRIG 1 REFRIG 2
Motor 1 Low Current, < 109,
Sensed on motor one
OFF OFF
Motor 2 Low Current, < 109,
Sensed on motor two
OFF OFF
Motor 1 High current > 255,
Sensed on motor one
OFF OFF
Motor 2 High current > 255,
Sensed on motor two
OFF OFF
REFRIG Maximum Run Time on compressor OFF OFF OFF OFF
SYRUP 1 Syrup Out Side One OFF
SYRUP 2 Syrup Out Side Two OFF
CO
2
OUT CO
2
Out OFF OFF
H
2
O H
2
O Out *OFF *OFF
SENSOR 1 Temp Sensor Inlet One OFF OFF OFF OFF
SENSOR 2 Temp Sensor Inlet Two OFF OFF OFF OFF
SENSOR 3 Temp Sensor Outlet OFF OFF OFF OFF
* The refrigeration system and carbonator shall continue to operate for 1.5 minutes after a water pressure loss
has been detected. If water pressure loss continues beyond 1.5 minutes, the refrigeration system and
carbonator will stop.