Henny Penny 500 Fryer User Manual


 
Model 500/600
The gas pressure regulator on the automatic gas valve is factory set as
follows:
Natural: 3.5 inches water column
Propane: 10.0 inches water column
The gas pressure regulator has been set by Henny Penny and
is not to be adjusted by the user.
Lighting Procedure - Solid State Ignition
1. Turn main power switch to OFF position.
2. Move “ON/OFF” selector on gas control valve to OFF position.
3. Wait a sufficient length of time to allow any gas which may have
accumulated in the burner compartment to escape (at least 5
minutes).
4. Move “ON/OFF” selector on gas control valve to ON position.
5. Turn main power switch to ON position.
6. Wait about 45 seconds for the burner to light.
7. Listen for the gas burner ignition.
It will be an audible sound due to the gas igniting at the gas
jets within the burner.
8. The burner lights and operates until the shortening temperature
reaches a preset temperature, and when tempearture light goes
out, set timer for desired length of time.
Do not leave the thermostat on for more than 10 seconds
without shortening in the frypot or damage to the frypot may
result.
9. The frypot should be cleaned per the instructions in Section 3.
10. The frypot must be filled to the proper level with shortening.
Refer to Filling or Adding Shortening Section.
Shutdown Procedure
1. Move “ON/OFF” selector on gas control valve to OFF position.
2. Turn main power switch to ON position.
2-8. GAS PRESSURE
REGULATOR SETTINGS
2-9. GAS PILOT & BURNER
LIGHTING AND
SHUTDOWN
PROCEDURE
710 2-9
Gas Control Valve
“ON/OFF” Selector