![](http://pdfasset.owneriq.net/0/3f/03f1e225-56cd-4801-acc2-77a067bbbcf7/03f1e225-56cd-4801-acc2-77a067bbbcf7-bg3f.png)
Model 500/600
Problem Cause Correction
PRESSURE SECTION (Continued)
Pressure does not • Not enough product in fryer • Place proper quantity of
build or product not fresh fresh product within frypot to
generate steam
• Metal shipping spacer not • Remove shipping spacer;
removed from deadweight see Unpacking Section
• Lid open or not latched • Close and latch lid
• Solenoid valve leaking or • Have solenoid valve checked or
not closing cleaned
• Deadweight assembly leaking • Have deadweight assembly
repaired
• Pressure not programmed • See Diagnostic Mode D 10;
if pressure settings have been
changed, have the controls
reintialized
• Lid gasket leaking • Reverse gasket or lid needs
adjusted
• Safety relief valve leaking. • Check and replace if necessary
FILTER SYSTEM SECTION
Filter motor runs • Pump clogged • Have pump cleaned
but pumps peanut oil
slowly • Filter line connection • Tighten all filter line
loose connections
• Solidified peanut oil • Clear all filter lines of solidified
in lines peanut oil
Filter switch on, • Defective COOK/PUMP switch • Have switch checked
motor does not run
• Defective motor • Have motor checked
• Motor thermal protector tripped • Reset thermal protector
per Filter Pump Motor
Thermal Protector Section
803 5-7