Henny Penny 500 Fryer User Manual


 
Model 500/600
5-4. INFORMATION MODE
DETAILS
11. OUTP H* P_
This mode displays the status of components and outputs. If the output
signal is detected, an identifying letter is displayed (see below), followed
by an “*”. If the output is off, “_” is displayed.
H = Heat output
P = Pressure output
If heat is on, “H*” shows in display. If heat is off, “H_” shows in
display
. If controls senses a problem with the heat output, “H*” shows
in display
, with the “*” flashing.
If pressure is on, “P*” shows in display. If pressure is off, “P_” shows
in display. If controls senses a problem with the pressure output, “P*”
shows in display, with the “*” flashing.
Press to view the “amps” status of each output.
“H
\
/” and “P
\
/” in the display means the amps are good. A flashing “X”
behind the H or P means a problem exists.
Press to view the no connect/ground (“NC/GD”) status of each
output. This monitors a possible problem with the relays on the output
PC board.
“H
\
/” and “P
\
/” in the display means everything on the output PC board
is good. A flashing “X” behind the H or P means a problem exists.
Press to view the outputs and inputs (see step 10) together.
Press to continue onto the POT TMP reading.
12. POT TMP
This step shows the present peanut oil temperature. The display shows
“12. POT TMP (temp.)”.
Press to continue onto the CPU TMP reading.
13. CPU TMP
This step shows the present PC board temperature.
Press to continue onto the ANALOG reading.
5-34 303