Henny Penny 500 Fryer User Manual


 
Model 500/600
5-4. INFORMATION MODE
DETAILS
5. TODAY’S DATA (automatically resets each day)
Press to step through the following data:
FUNCTION DISPLAY EX:
Today’s Date 5A. DATE APR-12
Time of day last heat-up was completed 5B. LAST HEAT 9:45A
Peak heat-up rate (°F/Sec) for last heat-up 5C. LAST RATE 0.82
Was last heat-up acceptable? 5D. LAST OK? YES
Heat cap. status (based on last 4 ht-ups) 5E. HEAT CAP GOOD
Number of monitored heat-ups today 5F. HEAT-UPS 2
Number of slow heat-ups 5G. SLOW HT’S 0
Max time to heat 270°F to 310°F today 5H. MAX HT TM 1:17
Lowest peak rate for today’s heat-ups 5I. MIN RATE 0.82
Maximum voltage today (when fryer on) 5J. MAX VOLT 99%
Minimum voltage today (when fryer on) 5K. MIN VOLT 95%
No. of “LOW VOLTAGE” warnings 5L. LO VOLT’S 0
Maximum amp draw today 5M. MAX AMPS 35
Minimum amp draw today 5N. MIN AMPS 33
Number of “Low Amps” warnings today 5O. LO AMP’S 0
Non-cooking time (hh:mm) while fryer was on 5P. IDLE HRS 1:23
Oil wear accumulated so far today 5Q. OIL WEAR 3
Total number of Cook Cycles today 5R. TOT CK’S 11
No. of cycles started before ready 5S. NOT RDY’S 2
No. cycles quit early (0:11 or more remaining) 5T. QUIT 11+ 0
No. cycles beeped *DONE* 21 sec or more 5U. DONE 21+ 1
Individual product cook counts 5V. Px CK CT 2
Individual product not detected counts 5W. Px NO DET 0
Individual product slow cook counts 5X. Px SLO CT 0
Individual product frozen or overloaded 5Y. Px FRZ/OV 0
During steps 5V through 5Y, press the product buttons (or
Manual Prog) to see data on individual product items.
Press to continue onto prev-day-sun log.
303 5-28