Henny Penny 500 Fryer User Manual


 
Model 500/600
5-4. INFORMATION MODE
DETAILS
8. OIL DATA (current batch; resets by Clean-Out Mode)
Press to step through the following data:
FUNCTION DISPLAY EX:
The day current batch of oil was started 8A. SINCE APR-1
Number of days with data included in totals 8B. DAYS CNT 10
Number of monitored heat-ups 8C. HEAT-UPS 75
Number of slow heat-ups 8D. SLOW HT’S 2
Max time to heat 270°F to 310°F 8E. MAX HT TM 3:25
Lowest peak rate of all heat-ups 8F. MIN RATE 0.43
Maximum voltage 8G. MAX VOLT 102%
Minimum voltage 8H. MIN VOLT 91%
No. of “LOW VOLTAGE” warnings 8I. LO VOLT’S 0
Maximum amp draw 8J. MAX AMPS 35
Minimum amp draw 8K. MIN AMPS 32
No. of “LOW AMPS” warnings 8L. LO AMP’S 0
Non-cooking time (hrs) while fryer was on 8M. IDLE HRS 43
Total oil wear accumulated 8N. TOT WEAR 278
Total number of Cook Cycles 8O. TOT CK’S 125
Number of cycles started before ready 8P. NOT RDY’S 7
No. cycles quit early (0:11 or more remaining) 8Q. QUIT 11+ 1
No. cycles beeped *DONE* 21 sec or more 8R. DONE 21+ 3
Individual product cook counts 8S. Px CK CT 77
Individual product not detected counts 8T. Px NO DET 3
Individual product slow cook counts 8U. Px SLO CT 0
Individual product frozen or overloaded 8V. Px FRZ/OV 1
During steps 8S through 8V, press the product buttons (or
Manual Prog) to see data on individual product items.
Press to continue onto prev oil data log.
303 5-31