Henny Penny 500 Fryer User Manual


 
Model 500/600
Problem Cause Correction
FILTER SYSTEM SECTION (Continued)
Motor hums but Clogged lines or pump Have pump and lines removed
will not pump and cleaned
Have pump seal, rotor
and rollers replaced
HEATING OF PEANUT OIL SECTION
Peanut oil will not heat Blown fuse or tripped circuit Reset breaker or replace fuse
breaker
Faulty cord and plug Check cord and plug
Faulty PC board Have control panel checked
Faulty or tripped high limit “E10” Reset high limit per Operating
Components Section; if high
limit doesn’t reset, have it
checked
Drain valve open “E15” Close drain valve
Possible faulty probe “E6” Have temperature probe
checked
• Possible faulty contactor See Diagnostic Modes D 4;
(electric models) see if “CHECK COILS,
CONTACTORS AND
WIRING” shows on display
Gas valve knob turned to the Make sure the gas valve knob
OFF position (gas models) is turned to ON
Faulty thermocouple on gas Have thermocouple checked
control valve (gas models)
• Faulty COOK/PUMP switch See Information Mode10
Faulty drain switch “E15” and check to see if the
Possible faulty gas control input code is present; if not,
have fryer checked by a
certified service technician
5-8 803