The gas regulator is preset at the factory at 3.5 inch water column (0.87
kPa) for natural gas (10.0 inch (2.49 kPa) for propane). If adjustment is
necessary, contact your local independent Henny Penny distributor.
The gas fryer requires 120 single phase, 60 Hertz, 10 or 5 amp, 2 wire
+ ground service. The gas fryer is factory equipped with a grounded
cord and plug for your protection against shock and should be plugged
into a 3 prong grounded receptacle. A wiring diagram is located behind
the front door.
Do not disconnect the ground (earth) plug. This fryer must be
adequately and safely grounded (earthed) or electrical shock
could result. Refer to local electrical codes for correct
grounding (earthing) procedures or in absence of local codes,
with The National Electrical Code, ANSI/NFPA No. 70-(the
current edition). In Canada, all electrical connections are to
be made in accordance with CSA C22.1, Canadian Electrical
Code Part 1, and/or local codes.
To avoid electrical shock, this appliance must be equipped
with an external circuit breaker which will disconnect all
ungrounded (unearthed) conductors. The main power switch
on this appliance does
not disconnect all line conductors.
2-10. PRESSURE
REGULATOR
ADJUSTMENT
(GAS ONLY)
2-11. ELECTRICAL
REQUIREMENTS
(GAS FRYER)