If the fryer has witnessed two or more low voltage warnings today, the
following report is displayed:
“D4: CAN’T TEST”
“D4: HEA
T CAPACITY”
“D4: DUE TO”
“D4: VOLTAGE”
“D4: PROBLEMS”
Otherwise, if the assessed heat capacity rating is presently “good” and
there has been at most one heat-up today that failed to achieve the
expected rate, the following report is displayed:
“D4: HEATING”
“D4: CAP
ACITY”
“D4: IS FINE”
Otherwise, if the heat capacity is presently assessed as “bad”, or
presently assessed as “good” but two or more heat-ups today have not
reached the expected heat-up rate, the following report sequence is
generated:
“D4: YOU HAD 75%”
“D4: SLOW HEATS”
“D4: TODAY”
(Press )
“D4: HAVE 20%”
“D4: SLOW HEATS”
“D4: THIS OIL”
(Press )
“D4: HAD 0%”
“D4: SLOW HEATS”
“D4: LAST OIL”
(Press )
If the heat capacity is assessed as bad (low heat-up rate on last heat-
up, and on three of the last four heat-ups), then the heating coils are
suspect and the following message is displayed:
“D4: CHECK COILS,”
“D4: CONTACTORS,”
“D4: AND WIRING”
5-3. DIAGNOSTIC MODE
DETAILS (Continued)
5-16 303