5-3. DIAGNOSTIC MODE
DETAILS (Continued)
D 3: Line Voltage Performance Report
This section displays information about how good the line voltage
supply has been for the present day and for the present batch of oil.
The controller continually monitors the line voltage supplied to the fryer
(when the fryer is on). If the line voltage drops below [90%] of its
nominal value, the controller signals a “LOW VOLTAGE” alarm. This
alarm sounds at the end of each Cook Cycle for which low voltage has
been detected. While not cooking, the low voltage alarm can sound as
frequently as every 30 minutes.
“[ ] around a value, such as [90%], means this value is
programmable and might change with later software versions.
Voltage Report for Today
If no low voltage warnings have been detected for the present day, the
controller shows, “D3: VOLTAGE OK, D3: TODAY “
If one or more low voltage warnings have been detected for the present
day, the following sequence example could be displayed:
“D3: YOU HAD 3”
“D3: LOW VOLTAGE”
“D3: WARNINGS”
“D3: TODAY”
(Press )
“D3: MIN VOLTAGE”
“D3: TODAY = 83%”
(Press )
“D3: MAX VOLTAGE”
“D3: TODAY = 101%”
(Press )