Henny Penny 500 Fryer User Manual


 
Model 500/600
If one or more low voltage warnings have been detected before today,
the following sequence is displayed:
“D3: BEFORE TODAY”
“D3: 27 LOW
VOLT”
“D3: WARNINGS”
“D3: ON THIS OIL”
(Press )
“D3: MIN VOLTAGE”
“D3: BEFORE
TODAY”
“D3: = 85%”
(Press )
“D3: MAX VOLTAGE”
“D3: BEFORE TODAY”
“D3: = 105%”
Press to advance to the next section.
D 4: Heating Capacity Report
This section reports the present status of the heating system.
The controller examines a history of heat-up data and determines
whether or not the heating system is operating normally. The heat
capacity is said to be bad only if the most recent heat-up failed to meet
the expected heat-up rate and three of the last four heat-ups also failed
to achieve the expected rate. That is, a single slow heat-up will not
trigger a slow heat warning. The slow heat warning is activated only
after repeated low-rate heat-ups is observed.
The controller can’t assess the integrity of the heating system if the fryer
has been experiencing voltage problems. Low heat rates observed in
this situation might be due to voltage problems rather than heater
problems.
5-3. DIAGNOSTIC MODE
DETAILS (Continued)