Amana RST Range User Manual


 
OPERATION AND SERVICE PROCEDURES
(Models RST359, 361, 362, 365, 399)
59 RC231002 Rev. 3
CLOCK TIMER
FUNCTION 11-12 13-14
MANUAL
0 0
DELAY IN AUTO
0 0
COOKING IN AUTO
X X
AUTO COMPLETE
0 0
O = OPEN X = CLOSED
Timer Switching Schedule
5. Push self-clean button in. The following should take
place immediately - three (3) hours (3:00) should
appear in the display, the letter "C" should appear on
the left side of the display, the oven-on symbol should
also appear on the left and both switches should be
closed. Manually, with "TIME SET" control, turn the
digital display down to one (1) minute. Allow the timer
to countdown to 0:00. Display should return to time
of day and the switches open. NOTE: A slight "click"
can be heard whenever the relay switches open or
close.
TO AVOID THE RISK OF ELECTRIC SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER
BEFORE SERVICING, UNLESS TESTING REQUIRES IT.