Amana RST Range User Manual


 
GENERAL INFORMATION
RC231002 Rev. 3 6
SPECIFICATIONS - Burner Ratings - RST
Non Sealed Nat 10,000 BTU/HR
Top Burner LP 7,000 BTU/HR
Sealed Top Nat 9,000 BTU/HR
Burner LP 7,000 BTU/HR
Cast Sealed RST/RSS
Top Burner
Large (3) Nat 9,000 BTU/HR
LP 8,000 BTU/HR
Small (1) Nat 7,000 BTU/HR
LP 6,000 BTU/HR
Oven Burner Nat 15,500 BTU/HR
Lower LP 15,000 BTU/HR
Broil Nat 15,500 BTU/HR
Burner LP 13,000 BTU/HR
Oven Burner Nat 12,000 BTU/HR
Upper LP 12,000 BTU/HR
BURNER ORIFICE SIZES - Universal Models
Non Sealed Top Burners are equipped with #54 double
coaxial orifices and universal pin.
Sealed Top Burners are equipped with a 4-#54 orifice
spud for natural gas and separately packed 4-#68 orifice
spud to convert to LP gas.
or
beginning October 22, 1990 at serial number F0430127550
the venturi type top burners are equipped with #54 double
coaxial orifices and universal pin.
Cast Sealed Top Burners are equipped with 3-#54 double
coaxial orifices with universal pins and 1-#56 double
coaxial orifice with universal pin.
Lower Oven Burner is equipped with a #50 double coaxial
orifice and universal pin.
Broil Burner is equipped with a #54 orifice spud and
separately packed orifice spud to convert to LP gas.
Upper Oven Burner is equipped with a #52 double coaxial
orifice and universal pin.
ELECTRICAL REQUIREMENTS
These ranges should be connected to a separate 115 volt,
60 cycle AC three-wire "U" ground receptacle, parallel
slots.
SPECIFICATIONS - Burner Ratings - RSS
NON SEALED
Top Burner Nat 10,000 BTU/HR
Top Burner LP 8,000 BTU/HR
Oven Burner Nat 15,5000 BTU/HR
Lower LP 15,500 BTU/HR
Broil Nat 15,500 BTU/HR
Burner LP 13,000 BTU/HR