Trane SYS-APM001-EN Water Dispenser User Manual


 
100 Chiller System Design and Control SYS-APM001-EN
References
1 Webb, R.L. and W. Li. “Fouling in Enhanced Tubes Using Cooling Tower
Water, Part I: Long-Term Fouling Data.” International Journal of Heat and
Mass Transfer 43, no. 19 (October 2000): 3567-3578.
2 Schwedler, M. and B. Bradley. “An Idea for Chilled-Water Plants Whose
Time Has Come...Variable-Primary-Flow Systems,” Engineers Newsletter
28, no. 3 (1999), Trane.
3 American Society of Heating, Refrigerating, and Air-Conditioning
Engineers. ASHRAE HVAC Systems and Equipment Handbook, Chapter
12, “Hydronic Heating and Cooling System Design” and Chapter 39,
“Cooling Towers.” ASHRAE, 2008.
4 American Society of Heating, Refrigerating, and Air-Conditioning
Engineers. ASHRAE Standard 147-2002: Reducing the Release of
Halogenated Refrigerants from Refrigeration and Air-Conditioning
Equipment and Systems. ASHRAE, 2002.
5 Air-Conditioning, Heating, and Refrigeration Institute. ARI Standard 550/
590–2003: Performance Rating of Water Chilling Packages Using the
Vapor Compression Cycle. AHRI, 2003.
6 American Society of Heating, Refrigerating, and Air-Conditioning
Engineers. ASHRAE Guideline 22: Instrumentation for Monitoring Central
Chilled-Water Plant Efficiency. ASHRAE, 2008.
7 American Society of Heating, Refrigerating, and Air-Conditioning
Engineers. ASHRAE Standard 140-2007: Standard Method of Test for the
Evaluation of Building Energy Analysis Computer Programs. ASHRAE,
2007.
8 American Society of Heating, Refrigerating, and Air-Conditioning
Engineers. ASHRAE GreenGuide: The Design, Construction, and
Operation of Sustainable Buildings. 2nd ed. ASHRAE, 2006.
9 Air-Conditioning, Heating, and Refrigeration Institute. ARI Standard 560–
1992: Absorption Water Chiller and Water Heating Package. AHRI, 1992.
10 Kelly, D.W. and T. Chan. “Optimizing Chilled-Water Plants.” Heating/
Piping/Air Conditioning (January 1999): 145-7.
11 Schwedler, M. and A. Nordeen. “Low Flow Works for Absorbers Too!”
Contracting Business (November 1998): 108-112.
12 Demirchian, G.H. and M.A. Maragareci. “The Benefits of Higher
Condenser-Water T at Logan International Airport Central Chilled-Water
Plant.” IDEA 88th Annual Conference Proceedings (1997): 291–300.
13 Eley, C. “Energy Analysis–Replacement of Chillers for Buildings 43, 47,
and 48.” Eley Associates, CA, April 1997.
14 Coad, W.J. “A Fundamental Perspective on Chilled-Water Systems,”
Heating/Piping/Air Conditioning (August 1998): 59-66.