5 - 42
5.2 Communication Setup
5.2.3 How to Set Up the Ethernet Connection
7 When using robot controller (CRnD-700)
For communications between GT SoftGOT1000 and the CRnD-700, the following setting items and
precautions are described below.
This section describes the system configuration to monitor the host as shown below.
Setting items
Refer to the following for how to set the N/W No., PLC No./PC No., IP address, and
port No. of the CRnD-700 and GT SoftGOT1000.
This section (6)
The following shows the procedures for communications with the CRnD-700.
(1) Before setting
(a) Precautions for monitoring
GT SoftGOT1000 cannot monitor other stations.
GT SoftGOT1000 cannot monitor CPUs on the other networks.
(b) Precautions for communication
When multiple network devices (including GT SoftGOT1000) are connected to the same
segment, the network load may increase, and the communication speed may slow down
between GT SoftGOT1000 and the PLC.
The following actions may improve the communication performance.
• Use a switching hub.
• Use the high-speed 100BASE-TX (100Mbps).
• Reduce the monitoring points of GT SoftGOT1000.
(2) Compatible models
Compatible models
CRnD-700
N/W No.
PC No.
IP address
Port No. :5001
<GT SoftGOT1000>
:1
:1
:192.168.0.18
N/W No.
PC No.
IP address
Port No. :5001
:1
:2
:192.168.0.19
<CRnD-700>