HOT DRINK SETUP/PROGRAMMING GUIDE
6700001 Page - 97 November, 2002
DBV JAM A bill is jammed in the acceptance path.
The unit will disable itself until the error
is corrected. Remove bill stuck in the
acceptance path. Cycle machine power
OFF and then ON.
DBV STACKR The stacker is open or removed. The
unit will disable itself until the error is
corrected. Install the stacker correctly.
CHK PRICE Price error detected and changed to
maximum - check prices.
NONE READY All selections are reported out of
service.
PV.ERR CUP 1 Cup ring 1 is out of service due to a
PosiVend™ error.
PV.ERR CUP 2 Cup ring 2 is out of service due to a
PosiVend™ error.
PV.ERR PCB PosiVend™ is ON but not working.
The last calibration sample was 255.
Check that the PosiVend™ PCB is
present at J34.
PV.ERR SNSR PosiVend™ is ON but not working.
The last calibration sample was 50.
Check for a blocked sensor or
disconnected harness.
AJP.TMR1 XX PosiVend™ is active and ring 1 anti-
jackpot timer is ON. XX is a value
between 1 and 99 in minutes.
AJP.TMR2 XX PosiVend™ is active and ring 2 anti-
jackpot timer is ON. XX is a value
between 1 and 99 in minutes, and
represents the amount of time left on
the anti-jackpot timer for this cup ring.
NO BREWER Brewer is missing or malfunctioning.