Crane Merchandising Systems 670 Hot Beverage Maker User Manual


 
HOT DRINK SETUP/PROGRAMMING GUIDE
November, 2002 Page - 20 6700001
3. Adjust the Air Pressure.
This control determines the system pressure provided
by the air compressor. Adjust as follows:
a. With the compressor running, pinch the brewer inlet
air tube.
b. Adjust the pressure to read 10 - 12 psi on the
gauge.
This will produce a pressure of 3 - 6 psi using regular
coffee and 8¼ oz cups. No further air
pressure adjustments should be
necessary.
4. Install Canisters.
1. Place the canister in position as shown.
2. Engage the pins on the motor shaft with the slots in the canister coupler.
3. Fit tabs on canister into the slots on the canister shelf.
4. To ensure canister is correctly engaged with the rear mounting bracket, gently
push down on the front edge of the canister lid.
626P0017
FILL
CANISTER
FILL
CANISTER
CANISTER
SHELF
CANISTER
SHELF
PINS ON MOTOR
SHAFT MUST ENGAGE
SLOTS IN CANISTER
COUPLER
PINS ON MOTOR
SHAFT MUST ENGAGE
SLOTS
IN CANISTER
COUPLER
PRESSURE
GAUGE
INCREASE
PRESSURE
ADJUST
CONTROL
INGREDIENTS SHELF
MONETAR
Y
PANEL