Agilent Technologies Agilent 86120C Ventilation Hood User Manual


 
3-45
Programming
Lists of Commands
:CALCulate3:DELTa:REFerence[:WAVelength] Selects the signal to be used as the reference for the
DELTa calculations.
I
:CALCulate3:DELTa:REFerence:WNUMber Selects the signal to be used as the reference for the
DELTa calculations.
I
:CALCulate3:DELTa:WAVelength[:STATe] Turns the delta wavelength measurement mode on and off. I
:CALCulate3:DELTa:WPOWer[:STATe] Turns the delta wavelength and power measurement mode
on and off.
I
:CALCulate3:DRIFt:DIFFerence[:STATe] Sets the drift calculation to subtract the minimum values
measured from the maximum values measured.
I
:CALCulate3:DRIFt:MAXimum[:STATe] Sets the drift calculation to return the maximum power
(frequency) values measured.
I
:CALCulate3:DRIFt:MINimum[:STATe] Sets the drift calculation to return the minimum power
(frequency) values measured.
I
:CALCulate3:DRIFt:PRESet Turns off all the drift states for DIFFerence, MAXimum,
MINimum, and REFerence.
I
:CALCulate3:DRIFt:REFerence:RESet Places the current list of signals into the reference list. I
:CALCulate3:DRIFt:REFerence[:STATe] Turns the drift state on and off so that CALC3:DATA? will
return the reference signal list.
I
:CALCulate3:DRIFt[:STATe] Turns the drift measurement calculation on and off. I
:CALCulate3:FPERot[:STATe] Turns the Fabry-Perot measurement mode on and off. I
:CALCulate3:FPERot:MEAN:[WAVelength]? Queries the mean wavelength of the selected modes. I
:CALCulate3:FPERot:MEAN:FREQuency? Queries the mean frequency of the selected modes. I
:CALCulate3:FPERot:MEAN:WNUMber? Queries the mean wavenumber of the selected modes. I
:CALCulate3:FPERot:PEAK:[WAVelength]? Queries the peak wavelength of the selected modes. I
:CALCulate3:FPERot:PEAK:FREQuency? Queries the peak frequency of the selected modes. I
:CALCulate3:FPERot:PEAK:WNUMber? Queries the peak wavenumber of the selected modes. I
:CALCulate3:FPERot:PEAK:POWer? Queries the peak power of the selected modes. I
:CALCulate3:FPERot:FWHM:[WAVelength]? Queries full width half-max wavelength of selected modes. I
:CALCulate3:FPERot:FWHM:FREQuency? Queries full width half-max frequency of selected modes. I
:CALCulate3:FPERot:FWHM:WNUMber? Queries full width half-max wavenumber of selected
modes.
I
:CALCulate3:FPERot:MODE:SPACing:[WAVelengt
h]?
Queries the mode spacing wavelength of the selected
modes.
I
:CALCulate3:FPERot:MODE:SPACing:FREQuenc
y?
Queries the mode spacing frequency of the selected
modes.
I
:CALCulate3:FPERot:MODE:SPACing:WNUMbe
r?
Queries the mode spacing wavenumber of the selected
modes.
I
Table 3-10. Programming Commands (3 of 5)
Command Description Code
Codes: S indicates a standard SCPI command. I indicates an instrument specific command.